Major Ratings and Characteristics of "I-Drive"


 

  • Spec of Automotive Wire Harness (AWG12)

Size AWG

Copper Stranding

Conductor OD Inches

Insulation Thickness

Finished OD Inches

Finished Weight lbs/Mft

OHMS Resistance/ Mft

Ampacity 30°C (86°F) Ambient

Ampacity 40°C (104°F) Ambient

12 AWG

(65/30) tinned

0.089

0.030

0.149

31

1.680

44

41

Note: Ampacities based on single conductor in free air, 30°C (86°F) or 40°C (104°F)

ambient temperature as specified, 105°C (221°F) conductor temperature, per table

310-17 of the NEC (adjusted for 105°C). Free air ratings assume a one cable diameter

spacing between adjacent conductors.

Insulation Properties

Properties

Results

Test methods

Specific Gravity (±.02)

1.30

ASTM D-792

Durometer Shore "A"

77/65

ASTM D-2240

(±.02) INST./15 seconds

Tensile Strength (60 mil)

2000

ASTM D-412

Elongation (%)

300

ASTM D-412

Brittle Point (C)

-55

ASTM D-746

Oxygen Index %

25.0

ASTM D-2863

Oil Aged 18 Hours @ 121°C

% Retention of Tensiles

129

UL Standard

% Retention of Elongation

72

UL Standard

Air Aged 7 Days @ 136°C

% Retention of Tensiles

109

ASTM D412-80

% Retention of Elongation

100

ASTM D412-80

Oil Aged 7 Days @ 60°C

% Retention of Tensiles

124

ASTM D412-80

% Retention of Elongation

89

ASTM D412-80

VW-1 Flame Test

Pass

UL Standard

Product Cold Bend Test

Pass

UL Standard

Voltage Rating600

UL Standard

 